  • When the Same Home Health Audit Finding Keeps Coming Back

November 25, 2026

When the Same Home Health Audit Finding Keeps Coming Back

Why a completed corrective action form is not the same as a fixed workflow

Written by Jamie Davis, Esq., CIPP/US, CCEP   

Introduction

Most home health leaders have lived through this cycle. An internal audit, a payer review, or a state inspection identifies a problem. The team updates a policy, holds an in-service, signs a corrective action form, and files it. Six months later, the same finding shows up again, sometimes in the same words.

The repeat finding is rarely a sign that staff do not care. More often, it is a sign that the corrective action addressed the paperwork around the problem instead of the workflow that produced it. This article is meant to help healthcare administrators and compliance officers tell the difference between a completed corrective action form and real evidence that the underlying process has changed.

Why a Policy Update Alone May Not Close a Finding

A policy describes what should happen. A finding describes what actually happened. When the two do not match, rewriting the policy can make the gap look closed on paper while leaving the day-to-day process untouched.

Federal regulations already point leaders toward measurement rather than documentation alone. The home health Quality Assessment and Performance Improvement (QAPI) condition of participation at 42 CFR 484.65 requires agencies to measure, analyze, and track quality indicators and to take actions that result in improvement, then track performance to make sure the improvements are sustained (https://www.ecfr.gov/current/title-42/chapter-IV/subchapter-G/part-484/subpart-B/section-484.65).

The HHS Office of Inspector General's General Compliance Program Guidance likewise describes auditing and monitoring, and responding to detected problems, as core elements of an effective compliance program (located for download at https://oig.hhs.gov/compliance/general-compliance-program-guidance/).

In my experience working with home health, hospice, and DME organizations, a repeat finding usually traces back to one of three gaps:

  1. The corrective action named a department or "staff" as responsible, but not a specific person.
  2. The fix was a one-time training with no follow-up check on whether behavior changed.
  3. No one defined what "fixed" would look like in numbers, so no one could tell whether it was.

Assign an Accountable Owner and a Measurable Check

A durable corrective action answers four questions in plain language:

  • Who owns it? Name one individual by role, such as the Director of Clinical Services, not "nursing."
  • What is changing in the workflow? Describe the step that will be done differently, by whom, and at what point in the process.
  • How will we measure it? Define a specific, countable check, such as the percentage of sampled records meeting the requirement.
  • When will we look again, and what result counts as closed? Set the review dates and the target in advance.

The last question matters most. A finding should be closed based on results over time, not on the date a form was signed. If the target is not met at the first review, the corrective action stays open and the root cause is revisited.

An Illustrative Example - The following example is a composite created for teaching purposes. It does not describe any specific agency or client.

An agency's internal record review finds that several visit notes do not document the patient's response to the skilled intervention provided. The agency's first corrective action is to update its documentation policy and hold a 30-minute in-service. The next quarterly review finds the same issue at nearly the same rate.

On a second look, the agency asks why the gap exists. It learns that the electronic visit note template has no prompt for patient response, and that clinicians completing notes late in the day are working from memory. The policy was never the problem. The template and the timing were.

The revised corrective action assigns the Director of Clinical Services as owner, adds a required patient-response field to the visit note template, and sets an expectation that notes be completed within a defined timeframe after the visit. The agency's quality lead pulls a random sample of visit notes each month and measures the percentage that document patient response. The agency sets a target in advance and agrees that the finding will not be closed until that target is met for three consecutive months.

This approach also supports the clinical record requirements at 42 CFR 484.110, which require the clinical record to include all interventions and the patient's responses to those interventions, with entries that are complete and appropriately authenticated, dated, and timed (https://www.ecfr.gov/current/title-42/chapter-IV/subchapter-G/part-484/subpart-C/section-484.110).

A Short Monitoring Routine Leaders Can Adapt

Leaders do not need a complex system to stop repeat findings. A simple, consistent routine is often enough:

  • Keep one open-findings log. List every open finding with its owner, the workflow change, the measure, the target, and the next review date.
  • Review the log at a standing meeting. Monthly is a practical cadence for most agencies. Each owner reports the latest number, not just a status.
  • Sample, do not assume. Pull a small random sample of records or transactions for each open finding rather than relying on self-reports.
  • Close on evidence. A finding moves to closed only after the target is met over a set period, and the supporting data is kept with the log.
  • Recheck later. Add closed findings to a lighter recheck schedule, such as six months out, so that a fix that slips is caught early.
  • Escalate patterns. If the same finding returns after closure, report it to senior leadership or the compliance committee and treat it as a root cause issue, not a training issue.

This routine fits naturally into an agency's existing QAPI program and compliance committee reporting, so it does not need to become a separate project.

Conclusion

A repeat audit finding is useful information. It tells leaders that the last fix changed the paperwork but not the process. By naming a single accountable owner, changing the actual workflow step, defining a measurable check, and closing findings only on evidence, home health organizations can turn corrective action from a filing exercise into lasting improvement. State inspectors, auditors, and payers notice the difference, and so do patients.

The views in this article are my own, based on my professional experience, and are provided for general educational purposes and not intended as consulting or legal advice.

About the Author Jamie Davis, Esq., CIPP/US, CCEP


Jamie Davis, Esq., CIPP/US, CCEP, is an attorney and the founder of Build & Comply Consulting, where she serves as a fractional Chief Compliance Officer for healthcare organizations, with a focus on home health, hospice, DME, and behavioral health.

Her work centers on healthcare compliance programs, privacy, licensure, and enrollment. https://buildandcomplyconsulting.com

Copyright © 2026 American Institute of Healthcare Compliance All Rights Reserved

 

TAGS